Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen angezeigt.

Link zu dieser Vergleichsansicht

Beide Seiten der vorigen RevisionVorhergehende Überarbeitung
en:grundlagenhandbuch:entgasungsoberflaechenberechnung [2026/08/03 13:32] – [Degassing efficiency of the process] paalen:grundlagenhandbuch:entgasungsoberflaechenberechnung [2026/08/03 13:36] (aktuell) – [Degassing efficiency of the process] paal
Zeile 112: Zeile 112:
 The degassing efficiency is evaluated with the degassing reference parameter of Schuler (Equation 9).  The degassing efficiency is evaluated with the degassing reference parameter of Schuler (Equation 9). 
  
-$$\frac{c_{Start} - c_{End}}{c_{Start} - c_{Equilibrium}} \sim \frac{\left(\frac{A_{POOL}}{t_{POOL}} + \frac{A_{FILM}}{t_{FILM}} + \frac{A_{GROUND}}{t_{GROUND}}\right)}{\dot{m}} \tag{9}$$+$$\frac{c_{Start} - c_{End}}{c_{Start} - c_{Equilibrium}} \sim \frac{\left(\frac{A_{POOL}}{\sqrt{t_{POOL}}} + \frac{A_{FILM}}{\sqrt{t_{FILM}}} + \frac{A_{GROUND}}{\sqrt{t_{GROUND}}}\right)}{\dot{m}} \tag{9}$$
  
 In this case taken place the determination for wetting and non-wetting polymer. For wetting polymer is the Equation 10 and for non-wetting polymer is the Equation 11 used. In this case taken place the determination for wetting and non-wetting polymer. For wetting polymer is the Equation 10 and for non-wetting polymer is the Equation 11 used.
  
-$$EK_{Wetting} = \frac{\left(\frac{A_{POOL}}{t_{POOL}} + \frac{A_{FILM}}{t_{FILM}} + \frac{A_{GROUND}}{t_{GROUND}}\right)}{\dot{m}} \tag{10}$$+$$EK_{Wetting} = \frac{\left(\frac{A_{POOL}}{\sqrt{t_{POOL}}} + \frac{A_{FILM}}{\sqrt{t_{FILM}}} + \frac{A_{GROUND}}{\sqrt{t_{GROUND}}}\right)}{\dot{m}} \tag{10}$$
  
-$$EK_{Non-Wetting} = \frac{\left(\frac{A_{POOL}}{t_{POOL}} + \frac{A_{FILM}}{t_{FILM}}\right)}{\dot{m}} \tag{11}$$+$$EK_{Non-Wetting} = \frac{\left(\frac{A_{POOL}}{\sqrt{t_{POOL}}} + \frac{A_{FILM}}{\sqrt{t_{FILM}}}\right)}{\dot{m}} \tag{11}$$
  
 The difference between both equation is that the surface area und renewal time at screw root is neglected, because in non-wetting case are not melt at screw root available. The difference between both equation is that the surface area und renewal time at screw root is neglected, because in non-wetting case are not melt at screw root available.